Click to enlarge image
|
Features
- Our products are equipped with a various series of types with LED operating
display lamps, built-in diodes (DC surge suppressors), built-in C-R circuit
(AC surge suppressors)
- Our products coils are AC4 rated (AC100/110, 110/120, 200/220, 220/240)
and DC2 rated(DC100/110).
- Our products with four poles are equipped with Arc Barrier.
- Our products can endure the voltage of AC 2,000V (for a minute).
- Our products contacts are gold plated to increase even small amount of load
and contact reliability.
Specification
Kinds
| Classification/Poles |
2 Poles |
4Poles |
| Rated voltage |
Mode |
Rated voltage |
Mode |
Basic type
(YM2-A, YM4-A) |
AC6, 12, 24, 50, 100/110, 110/120,
200/120, 220/240 |
YM2-A |
AC6, 12, 24, 50, 100/110,
110/120, 200/120, 220/240 |
YM4-A |
| DC6, 12, 24, 48, 100/110 |
DC6, 12, 24, 48, 100/110 |
| LED operating display lamps (YM2-L, YM4-L)
|
AC6, 12, 24, 50, 100/110,
110/120, 200/120, 220/240 |
YM2-L |
AC6, 12, 24, 50, 100/110,
110/120, 200/120, 220/240 |
YM4-L |
| DC6, 12 ,24, 48, 100/110 |
DC6, 12, 24, 48, 100/110 |
Interior diodes
(YM2-LD, YM4-LD) |
DC6, 12, 24, 48, 100/110 |
YM2-D |
DC6, 12, 24, 48, 100/110 |
YM4-D |
| LED operating display lamps and interior diodes (YM2-LD,
YM4-LD) |
DC6, 12, 24,48, 100/110 |
YM2-LD |
DC6, 12, 24,48, 100/110 |
YM4-LD |
| LED operating display lamps and interior C-R (YM2-LCD,
YM4-LCR) |
AC6, 12, 24, 50, 100/110,
110/120, 200/120, 220/240 |
YM2-LCR |
AC6, 12, 24, 50, 100/110,
110/120, 200/120, 220/240 |
YM4-LCR |
Characteristics
|
Items/Kinds
|
Basic pttem |
LED operating display lamps and interior
diodes |
| Contact resistance |
Max. 50mΩ (by voltage drop DC
6V 1A) |
Operating time (at nominal voltage)
|
Max. 20ms |
Release time (at nominal voltage)
|
Max. 20ms |
| Max. switching frequency |
Mechanical |
18,000/per hour |
| Electrical |
1,800/per hour (rated current)
|
| Insulation resistance |
Min. 100MΩ (DC 500V Megger)
|
| Dielectric strength |
AC 2000V(50/60Hz) for 1 minute
(1000V between same pole contacts) |
| Vibration resistance |
Functional |
10 to 50Hz at double amplitude
of 1.0mm |
| Destructive |
10 to 50Hz at double amplitude
of 1.0mm |
| Shock resistance |
Functional |
1,000 m/s2 (about
100G) |
| Destructive |
200 m/s2 (about
20G) |
| Life expectancy |
Mechanical |
Min. AC: 50,000,000 operations, 4 poles:
200,000 operations (switching frequency: 18,000 times per hour) |
| Electrical |
Min. 2 poles: 500,000 operations, 4 poles:
200,000 operations(switching frequency: 18,000 times rated load) |
|
|
|
|
| |
|
|
|