Features
Specification
Kinds| Classification/Poles | 2 Poles | 4Poles | ||
| Rated voltage | Mode | Rated voltage | Mode | |
| Basic type (YM2-A, YM4-A) |
AC6, 12, 24, 50, 100/110, 110/120, 200/120, 220/240 | YM2-A | AC6, 12, 24, 50, 100/110, 110/120, 200/120, 220/240 | YM4-A |
| DC6, 12, 24, 48, 100/110 | DC6, 12, 24, 48, 100/110 | |||
| LED operating display lamps (YM2-L, YM4-L) | AC6, 12, 24, 50, 100/110, 110/120, 200/120, 220/240 | YM2-L | AC6, 12, 24, 50, 100/110, 110/120, 200/120, 220/240 | YM4-L |
| DC6, 12 ,24, 48, 100/110 | DC6, 12, 24, 48, 100/110 | |||
| Interior diodes (YM2-LD, YM4-LD) |
DC6, 12, 24, 48, 100/110 | YM2-D | DC6, 12, 24, 48, 100/110 | YM4-D |
| LED operating display lamps and interior diodes (YM2-LD, YM4-LD) | DC6, 12, 24,48, 100/110 | YM2-LD | DC6, 12, 24,48, 100/110 | YM4-LD |
| LED operating display lamps and interior C-R (YM2-LCD, YM4-LCR) | AC6, 12, 24, 50, 100/110, 110/120, 200/120, 220/240 | YM2-LCR | AC6, 12, 24, 50, 100/110, 110/120, 200/120, 220/240 | YM4-LCR |
|
Items/Kinds |
Basic pttem | LED operating display lamps and interior diodes | |
| Contact resistance | Max. 50mΩ (by voltage drop DC 6V 1A) | ||
| Operating time (at nominal voltage) |
Max. 20ms | ||
| Release time (at nominal voltage) |
Max. 20ms | ||
| Max. switching frequency | Mechanical | 18,000/per hour | |
| Electrical | 1,800/per hour (rated current) | ||
| Insulation resistance | Min. 100MΩ (DC 500V Megger) | ||
| Dielectric strength | AC 2000V(50/60Hz) for 1 minute (1000V between same pole contacts) | ||
| Vibration resistance | Functional | 10 to 50Hz at double amplitude of 1.0mm | |
| Destructive | 10 to 50Hz at double amplitude of 1.0mm | ||
| Shock resistance | Functional | 1,000 m/s2 (about 100G) | |
| Destructive | 200 m/s2 (about 20G) | ||
| Life expectancy | Mechanical | Min. AC: 50,000,000 operations, 4 poles: 200,000 operations (switching frequency: 18,000 times per hour) | |
| Electrical | Min. 2 poles: 500,000 operations, 4 poles: 200,000 operations(switching frequency: 18,000 times rated load) | ||
Other products from this supplier
Browse: Manufacturer Directory Premium Suppliers Site Map
About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy
Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese
Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838